Industry News

Anti-static finger sets of surface resistance test

Anti-static finger sets of surface resistance test
 
A sample to be tested into the insulation board
2 megger mini coaxial electrodes connected by cable color coding megger
3 Tap the coaxial electrode in the test sample, so that half of the electrode indentation readings
4 Click method to test the remaining sample
5 Surface Resistance Standard: ≥ 1.0 × 10 ^ 5 ohms to <1.0 × 10 ^ 11 ohm
 
Anti-static finger sets the volume resistance test
1 megger "Input" terminal is connected to a metal plate, "Test Voltage" jack insert a grounded wrist strap banana plug, "Shield Grounding" Ground
2 Test personnel wearing an antistatic wrist strap and finger sets to be tested, the voltage megger reads and records
Three sets of fingers will be tested with a finger pressed against the metal plate, to be read after the reading to stabilize and record the number of
4 Click method to test the remaining sample
5 volume resistance Standard: ≥ 1.0 × 10 ^ 5 ohms to <1.0 × 10 ^ 11 ohm